Sakura COOLING ONLY Manual de usuario Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 20
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
Neutral? =>
x-tra i medium
Firing chart for first phase:
Drying Starting Vacuum starting Rate of
temp. temp. heat increase
5–7 min. 450°C 450°C 60°C/min.
Final temp. Retention Vacuum Surface
time appearance
850°C 1–2 min. 1–2 min. matte finish
10
The use of
bright, medium
and
dark x-tra
incisals
enables the adjustment of the crown’s
colour in the final stage without having to polish
the restoration.
Firing chart for second phase:
Drying Starting Vacuum starting Rate of
temp. temp. heat increase
3–5 min. 450°C 450°C 60°C/min.
Final temp. Retention Vacuum Surface
time appearance
845°C 1–2 min. 1–2 min. matte finish
11
The crown after the first firing
10
Example: A3 crowns with...
x-tra i bright
applied before the second firing
11a
Darker? =>
x-tra i dark
Lighter? =>
x-tra i bright
The crown after the second firing
11b
bright medium dark
12
A slightly darker tone:
The colour value can be very accurately controlled
using
x-tra incisals bright
,
medium
and
dark.
For example, you can use
x-tra i dark
if the processing
instructions indicate that the cervical should be a bit
darker
SAKURA
interaction
Medium
x-tra incisal
SAKURA
interaction
Dark
x-tra incisal